Air/Water Cooled Water Chiller VFD (KACAWC-AD-VV | KACWWC-HH-EV Series)
Features
- Technical Design: Emphasizes advanced engineering for optimal performance.
- Direct Cooling: Ideal for air blown film lines.
- Temperature Consistency: Maintains stable air temperature for improved film quality.
- Quick Temperature Adjustment: Achieves desired temperatures rapidly.
- Power Efficiency: Adjusts consumption based on requirements; includes hot gas bypass for partial load control.
- Accessible Housing: Easy access to all components.
- Microcontroller: Text display, flow diagram, and fault indication.
- Digital Temperature Display: Shows air inlet and outlet temperatures.
- Air Flow Switch: Alerts to low air flow conditions.
- ROI: Attractive return on investment with demand control mode and BMS compatibility.
- Installation: Easy and quick, with ASME stamp option.
- Eco-Friendly: Designed with environmental considerations.
CHILLER AIR COOLED VFD | HEAT TRANSFER (KACAWC VFD SERIES)
MODEL | NOMINAL CAPACITY TR |
WATER RESERVIOR (LTR) | MAXIMUM FLOW TO PROCESS EVAP.LPM |
LENGTH (L) (MM) |
WIDTH (W) (MM) |
HEIGHT (H) (MM) |
PROCESS CONNECTION (INCH) | CONNECTED LOAD (KW) | MAIN MCCB RATING | MINIMUM CABLE SIZE COPPER | VOLTAGE | APPROX WEIGHT (KG) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MIN | MAX | ||||||||||||
KACAWC-AD-V-40 VFD | 3 | 12 | 200 | 230 | 1680 | 1100 | 1560 | 1 1/2″ | 16.8 | 63 AMP | 10.0 SQ MM | 415V,3PH,50HZ | 750 |
KACAWC-AD-V-70 VFD | 5 | 16 | 250 | 360 | 2050 | 1450 | 1940 | 2″ | 22 | 80 AMP | 16 SQ. MM | 415V,3PH,50HZ | 975 |
KACAWC-AD-V-105 VF | 7.5 | 29 | 400 | 450 | 2500 | 1680 | 2030 | 2″ | 33 | 100 AMP | 25 SQ MM | 415V,3PH,50HZ | 1500 |
CHILLER WATER COOLED VFD | HEAT TRANSFER (KACWWC VFD SERIES)
MODEL | NOMINAL CAPACITY TR |
WATER RESERVIOR (LTR) | MAXIMUM FLOW TO PROCESS EVAP.LPM |
LENGTH (L) (MM) |
WIDTH (W) (MM) |
HEIGHT (H) (MM) |
PROCESS CONNECTION (INCH) | CONNECTED LOAD (KW) | MAIN MCCB RATING | MINIMUM CABLE SIZE COPPER | VOLTAGE | CONDENS OR PUMP FLOW | COOLING TOWER CAPACITY TR |
APPROX WEIGHT (KG) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MIN | MAX | ||||||||||||||
KACAWC-HH-E-40 VFD | 3.5 | 14 | 200 | 230 | 1680 | 1100 | 1560 | 1 1/2″ | 14 | 63 AMP | 10.0 SQ MM | 415V,3PH,50HZ | 250 | 30 | 750 |
KACAWC-HH-E-70 VFD | 6 | 20 | 250 | 360 | 2050 | 1450 | 1940 | 2″ | 16.2 | 80 AMP | 16 SQ. MM | 415V,3PH,50HZ | 360 | 50 | 975 |
KACAWC-HH-E-105 VF | 9 | 32.6 | 400 | 450 | 2500 | 1680 | 2030 | 2″ | 26.5 | 100 AMP | 25 SQ MM | 415V,3PH,50HZ | 600 | 70 | 1500 |